CONSTANT CLEAN
FILTRATION WITH SMART LOGIC
Constant Clean
Filtration
Your spa is automatically preset to filter itself using the jet pump on low-speed for
three hours twice in a 24 hour period. The first filter cycle will begin one minute after
the spa is energized. The second filter cycle will begin 12 hours after the first cycle. See
PROGRAM FILTER to adjust cycles.
Smart Logic
This feature ensures that the spa water will be properly filtered after each spa use. 30
minutes after the spa light or jet pump has been deactivated, the pump runs on high-
speed for five minutes, then on low-speed to filter the water for four hours.
Heat Demand Operation
In addition to those situations mentioned above, the pump will circulate on low-speed
whenever the thermostat calls for heat.
SOLID-STATE Q
3
OZONATOR
The Q
3
Ozonator will function during all filter cycles. It will be disabled for one hour
whenever a pump or light pad is pressed. At the conclusion of the hour, the low-speed
pump and ozonator will run for four hours.
HEAT MODE
The spa’s heat mode can be adjusted to one of three different settings.
Standard Mode: The spa water will heat to the temperature as set at the Bather’s
panel. In this mode the filtration pump will turn on for one minute every half-hour and
“poll” or check the water. If heat is needed the unit will heat to the set temperature.
LCD display will steadily read actual temperature in this mode.
Economy Mode: In this mode the spa will only heat to the set temperature during a
programmed filter cycle. LCD display will alternately flash Ecn” with actual temperature when
spa is up to set temperature. LCD will steadily display “Ecn” when spa is below set
temperature.
Sleep Mode: The spa will only heat to 20° F below the set temperature. Heater will
only function during a programmed filter cycle. LCD display will alternately flash “SLP”
with the actual temperature when spa is up to set temperature. LCD will steadily
display “SLP” when spa is below set temperature.
For most applications, the Standard Mode should be used. If you are in a warm weather
climate and the spa does not require as much heat, the Economy Mode may work best.
For a vacation home or for very infrequent use, the Sleep Mode will provide filtration
and circulation with lower energy demand.
Your spa comes preset in the Standard Mode. To change this selection, press the HEAT
MODE pad and continue to press it until the desired setting is reached (Std, Ecn, or SLP).
When you have reached the desired setting, press the TEMP SET pad to select that
mode and exit programming. (TEMP SET pad must be pressed within ten seconds for
the selection to take effect.)
SYSTEM LOCK
After selecting filtration and heat modes, press SYSTEM LOCK pad, then immediately press
TEMP SET pad to preserve the operational settings and ensure against inadvertent changes.
Unlock the panel by repeating the procedure. Lock is indicated by LED light “SECURED”. Jets
and light will continue to function in System Lock.